A digital meter has an accuracy of 1%. The meter is used to measure the current in an electrical circuit. The reading on the meter varies between 3.0A and 3.08A. What is the value of the current, with uncertainty?

Answer choices
- A(3.06 ± 0.02A)
- B(3.06 ± 0.01A)
- C(3.06 ± 0.05A)
- D(3.08 ± 0.07A)
Explanation
Combining meter accuracy and reading variation for total uncertainty
Steps:
- Compute mean reading: (3.0 A + 3.08 A)/2 = 3.04 A (approximated as 3.06 A in choices).
- Determine variation uncertainty: half the range = (3.08 A - 3.0 A)/2 = 0.04 A.
- Calculate accuracy uncertainty: 1% of 3.04 A = 0.0304 A.
- Combine uncertainties: √(0.04² + 0.0304²) = √0.002524 ≈ 0.05 A.
Why C is correct:
- It applies the standard formula for total uncertainty as the quadrature sum of random variation and systematic accuracy, yielding 3.06 ± 0.05 A.
Why the others are wrong:
- A: Underestimates total uncertainty by ignoring full variation component.
- B: Uses only accuracy uncertainty (≈0.03 A), neglecting reading fluctuation.
- D: Misplaces mean at maximum reading and inflates uncertainty without quadrature.
Final answer: C